There are various alternatives of format available with fire detection systems, they all operate on the same principle – A sensor detects, the main panel recognises the difference and then alerts people of the situation that a fire has occurred.
The sensing device can be a humble break glass which indicates that the fire was found by an individual who then manually triggered the system. More complex devices spot either carbon monoxide, smoke, flames or heat. Usually, heat and flame sensors are the least quick as the fire would be well ablaze by the time they trigger.
Informing others is achieved by two techniques: Strobes and sounders all through a premises and digital alerts such as getting a fire brigade response by automatically sharing data with a monitoring centre.
The fire detection system format can differ based on several factors: budget, complexity of design , building size, business processes, fire-risk-assessment findings and insurer’s requirements. The main four formats are: Addressable, Conventional, Wireless and Analogue Addressable.
Conventional Fire Alarm Installation Bradford
Conventional detection systems have sensors wired together in sets to give a simple area of where the fire is e.g. offices, warehouse etc. Each group of units is referred to as a zone. A zone diagram by the control unit then demonstrates where the fire has been detected. It is a basic system but satisfactory for most medium and small sized businesses.
Addressable Fire Alarm Installation Bradford
Addressable systems likewise cable detecors together but crucially they can show accurately which device has alarmed. Lots more devices can be put on a loop. The devices operate like conventional components but have the ability to signify their address by throwing binary switches on the sensor. They are often used in bigger premises.
Analogue Addressable Fire Alarm Installation Bradford
Analogue Addressable systems are thought of as intelligent fire alarm systems. The devices in addressable and conventional systems are quite simple however in an analogue addressable set up the devices have some built-in processing and can decide whether they are in alarm, have a short circuit or require cleaning. Similarly, sirens and other components can be put on on the same loop making planning very adaptable. These are appropriate for larger, complex premises and enterprises. Wireless Fire Alarm Installation Bradford